Trimble X7/X9 - Diagnostic Report
Requirements
Before creating a diagnostic report there will be some requirements that need to be met.
- The report must be run in an area where the scanner can’t be disturbed.
- No People
- No strong vibrations
- You must use the Carbon fiber tripod legs to set the scanner on.
- You must have a battery with at least 50% or more charge.
Instructions
- Open Field Link and Turn on your scanner
- Select the Device menu icon
- Select the Scanner Icon on on the bottom left of the screen
- Then select the Scanner that appears on the center list of the screen
- If the Scanner does not appear on the screen press the find button on the bottom of the screen
- Once the Scanner is selected press the Connect icon
- The scanner will connect then you will select the diagnostic icon on the bottom right of the screen
Overview
The scanner will go through the diagnostic process and a report will appear on the screen once it's completed. A list format will display the components that passed represented by the color GREEN and if any component failed it will display the color RED.
Now press the save button on the bottom right and a copy will be saved into your C: Drive on your tablet. Which can be found by opening the file explorer and following this path (Documents/Field Links/PROJECT NAME/Reports/Diagnostic Report)
Related Articles
Trimble Software & Firmware
Trimble Software & Firmware Welcome to BuildingPoint Support's Trimble Software and Firmware portal. By following this page, you can stay up to date with the latest software and firmware for all your Trimble technology. To receive notifications, ...
Trimble X-Series Scanners - SD Card Formatting
The Trimble X-Series Scanners ship with a 32GB SD card, formatted in the FAT32 format. Most larger SD cards (over 32GB) are formatted in ExFAT format, and must be converted over to FAT32. In order to take advantage of newer and larger cards (such as ...
Daily Layout Summary Report Preview Fails
Issue Error occurs when attempting to preview a Daily Layout Summary Report. Observed behavior: Report fails when clicking Preview Issue occurs consistently within the affected project Primary Cause The issue is caused by the use of an unsupported ...
Trimble RealWorks Installation Guide
Trimble RealWorks – Installation Guide Overview Trimble RealWorks is desktop software used for 3D point cloud processing, registration, and analysis. This guide explains how to install RealWorks, activate licensing, and handle common issues. 1. ...
Trimble T100 - Trimble Update Viewer/Health Monitor Installation Guide
Installing the Trimble Update Tool Starting in Q3 2023, Trimble devices began shipping with the Trimble Update Tool pre-installed. If your device does not have it, follow these steps to install it manually: Manual Installation Steps Go to the Trimble ...